IOP  Select  IOP Journals  For Authors  For Referees
Collected Articles from the Institute of Physics Login | Create account
HomeSearchPersonalization:E-mail AlertsFeedback
-> Display content by:SUBJECTJOURNALMONTH
J. Micromech. Microeng. 6 (September 1996) 320-329   doi: 10.1088/0960-1317/6/3/004

Comb-drive actuators for large displacements


Rob Legtenberg, A W Groeneveld and M Elwenspoek
MESA Research Institute, University of Twente, PO Box 217, 7500 AE Enschede, The Netherlands

Abstract. The design, fabrication and experimental results of lateral-comb-drive actuators for large displacements at low driving voltages is presented. A comparison of several suspension designs is given, and the lateral large deflection behaviour of clamped - clamped beams and a folded flexure design is modelled. An expression for the axial spring constant of folded flexure designs including bending effects from lateral displacements, which reduce the axial stiffness, is also derived. The maximum deflection that can be obtained by comb-drive actuators is bounded by electromechanical side instability. Expressions for the side-instability voltage and the resulting displacement at side instability are given. The electromechanical behaviour around the resonance frequency is described by an equivalent electric circuit. Devices are fabricated by polysilicon surface micromachining techniques using a one-mask fabrication process. Static and dynamic properties are determined experimentally and are compared with theory. Static properties are determined by displacement-to-voltage, capacitance-to-voltage and pull-in voltage measurements. Using a one-port approach, dynamic properties are extracted from measured admittance plots. Typical actuator characteristics are deflections of about at driving voltages around 20 V, a resonance frequency around 1.6 kHz and a quality factor of approximately 3.

Print publication: Issue 3 (September 1996)
Received 30 November 1995, accepted for publication 4 June 1996

   PDF (282 KB) | References | Articles citing this article
Setup information is available for Adobe Acrobat.
EndNote, ProCite ® and Reference Manager ® are registered trademarks of ISI Researchsoft.

Find related articles





 
Copyright © Institute of Physics and IOP Publishing Limited 2009.
Use of this service implies that the user has read and agrees to the terms and conditions of use.
Systematic downloading of files is prohibited.