journals.iop.org home page electronic journals * User guide   * Site map   | Quick Search:Help  
Biomedical Materials
Athens/Institutional login
IOP login: Password:   
Create account | Alerts | Contact us
Journals Home | Journals List | EJs Extra | This Journal | Search | Authors | Referees | Librarians | User Options | Help |

Effect of argon purity on mechanical properties, microstructure and fracture mode of commercially pure (cp) Ti and Ti-6Al-4V alloys for ceramometal dental prostheses

José Bauer et al 2009 Biomed. Mater. 4 065002 (7pp)   doi: 10.1088/1748-6041/4/6/065002  Help

   PDF (1.08 MB) | References

José Bauer1,4, Suelen Cella2, Marcelo M Pinto2, Leonardo E Rodrigues Filho2, Alessandra Reis3 and Alessandro D Loguercio3
1 Department of Dentistry I, School of Dentistry, University Federal of Maranhão, Campus Universitário do Bacanga, Av. dos Portugueses, s/n, 65085680, São Luis/MA, Brazil
2 Department of Dental Materials, School of Dentistry, University of São Paulo, Av. Prof. Lineu Prestes, 2227, 05508-900, São Paulo/SP, Brazil
3 Department of Restorative Dentistry, Universidade Estadual de Ponta Grossa Av. General Carlos Cavalcanti, 4748, Bloco M, Sala 64 A, 84030-900, Ponta Grossa/PR, Brazil
4 Author to whom any correspondence should be addressed
E-mail: jrob@usp.br

Abstract. Provision of an inert gas atmosphere with high-purity argon gas is recommended for preventing titanium castings from contamination although the effects of the level of argon purity on the mechanical properties and the clinical performance of Ti castings have not yet been investigated. The purpose of this study was to evaluate the effect of argon purity on the mechanical properties and microstructure of commercially pure (cp) Ti and Ti-6Al-4V alloys. The castings were made using either high-purity and/or industrial argon gas. The ultimate tensile strength (UTS), proportional limit (PL), elongation (EL) and microhardness (VHN) at different depths were evaluated. The microstructure of the alloys was also revealed and the fracture mode was analyzed by scanning electron microscopy. The data from the mechanical tests and hardness were subjected to a two-and three-way ANOVA and Tukey's test (α = 0.05). The mean values of mechanical properties were not affected by the argon gas purity. Higher UTS, PL and VHN, and lower EL were observed for Ti-6Al-4V. The microhardness was not influenced by the argon gas purity. The industrial argon gas can be used to cast cp Ti and Ti-6Al-4V.

Print publication: Issue 6 (December 2009)
Received 13 May 2009, in final form 8 August 2009
Published 30 October 2009

Bookmark and Share Post to CiteUlike | Post to Connotea | Post to Bibsonomy

 

Find related articles





Article options

Authors & Referees

PhysicsWorld, subscribe noweprintweb.org - Your address for E prints
 
Content finder
  Full Search
  Help


  
Setup information is available for Adobe Acrobat.
EndNote, ProCite ® and Reference Manager ® are registered trademarks of ISI Researchsoft.
Copyright © Institute of Physics and IOP Publishing Limited 2009.
Use of this service is subject to compliance with the Terms and Conditions of use. In particular, reselling and systematic downloading of files is prohibited.
Help: Cookies | Data Protection. Privacy policy Disclaimer
 
Bioinspiration and Biomimetics reasearch banner