journals.iop.org home page electronic journals * User guide   * Site map   | Quick Search:Help  
Physiological Measurement
Athens/Institutional login
IOP login: Password:   
Create account | Alerts | Contact us
Journals Home | Journals List | EJs Extra | This Journal | Search | Authors | Referees | Librarians | User Options | Help |

Estimating intratidal nonlinearity of respiratory system mechanics: a model study using the enhanced gliding-SLICE method

Stefan Schumann et al 2009 Physiol. Meas. 30 1341-1356   doi: 10.1088/0967-3334/30/12/004  Help

   PDF (926 KB) | References

Stefan Schumann1,5, Boris Burcza1, Christoph Haberthür2, Michael Lichtwarck-Aschoff3,4 and Josef Guttmann1
1 Department of Anaesthesiology, Division for Experimental Anaesthesiology, University Medical Centre of Freiburg, Germany
2 Department of Anaesthesiology, Section for Surgical Intensive Care, Kantonsspital Luzern, Switzerland
3 Department of Anaesthesiology and Surgical Intensive Care, Central Hospital, Augsburg, Germany
4 Department of Surgical Sciences, Section of Anaesthesiology, University of Uppsala, Uppsala, Sweden
5 Author to whom any correspondence should be addressed
E-mail: stefan.schumann@uniklinik-freiburg.de

Abstract. In the clinical situation and in most research work, the analysis of respiratory system mechanics is limited to the estimation of single-value compliances during static or quasi-static conditions. In contrast, our SLICE method analyses intratidal nonlinearity under the dynamic conditions of mechanical ventilation by calculating compliance and resistance for six conjoined volume portions (slices) of the pressure–volume loop by multiple linear regression analysis. With the gliding-SLICE method we present a new approach to determine continuous intratidal nonlinear compliance. The performance of the gliding-SLICE method was tested both in computer simulations and in a physical model of the lung, both simulating different intratidal compliance profiles. Compared to the original SLICE method, the gliding-SLICE method resulted in smaller errors when calculating the compliance or pressure course (all p < 0.001) and in a significant reduction of the discontinuity error for compliance determination which was reduced from 12.7 ± 7.2 cmH2O s L−1 to 0.8 ± 0.3 cmH2O s L−1 (mathematical model) and from 7.2 ± 3.9 cmH2O s L−1 to 0.4 ± 0.2 cmH2O s L−1 (physical model) (all p < 0.001). We conclude that the new gliding-SLICE method allows detailed assessment of intratidal nonlinear respiratory system mechanics without discontinuity error.

Keywords: respiratory system, intratidal compliance, resistance, dynamic pressure base, SLICE method

Print publication: Issue 12 (December 2009)
Received 29 May 2009, accepted for publication 2 October 2009
Published 28 October 2009

Bookmark and Share Post to CiteUlike | Post to Connotea | Post to Bibsonomy

 

Find related articles






Article options

Authors & Referees

IOP Journal Archiveeprintweb.org - Your address for E prints
 
Content finder
  Full Search
  Help


  
Setup information is available for Adobe Acrobat.
EndNote, ProCite ® and Reference Manager ® are registered trademarks of ISI Researchsoft.
Copyright © Institute of Physics and IOP Publishing Limited 2009.
Use of this service is subject to compliance with the Terms and Conditions of use. In particular, reselling and systematic downloading of files is prohibited.
Help: Cookies | Data Protection. Privacy policy Disclaimer
 
Bioinspiration and Biomimetics reasearch banner