journals.iop.org home page electronic journals * User guide   * Site map   | Quick Search:Help  
Physiological Measurement
Athens/Institutional login
IOP login: Password:   
Create account | Alerts | Contact us
Journals Home | Journals List | EJs Extra | This Journal | Search | Authors | Referees | Librarians | User Options | Help |

Improvement of ballistocardiogram processing by inclusion of respiration information

Kouhyar Tavakolian et al 2008 Physiol. Meas. 29 771-781   doi: 10.1088/0967-3334/29/7/006  Help

   PDF (264 KB) | References

Kouhyar Tavakolian, Ali Vaseghi and Bozena Kaminska
Computational and Integrative Bio-Engineering Research Laboratory (CIBER), School of Engineering Science, Simon Fraser University, 8888 University Drive, Burnaby, BC V5A 1S6, Canada
E-mail: kouhyart@sfu.ca and kaminska@sfu.ca

Abstract. In this paper a novel methodology for processing of a ballistocardiogram (BCG) is proposed in which the respiration signal is utilized to improve the averaging of the BCG signal and ultimately the annotation and interpretation of the signal. Previous research works filtered out the respiration signal while the novelty of the current research is that, rather than removing the respiration effect from the signal, we utilize the respiration information to improve the averaging and thus analysis and interpretation of the BCG signal in diagnosis of cardiac malfunctions. This methodology is based on our investigation that BCG cycles corresponding to the inspiration and expiration phases of the respiration cycle are different in morphology. BCG cycles corresponding to the expiration phase of respiration have been proved to be more closely related to each other when compared to cycles corresponding to inspiration, and therefore expiration cycles are better candidates to be selected for the calculation of the averaged BCG signal. The new BCG average calculated based on this methodology is then considered as the representative and a template of the BCG signal for further processing. This template can be considered as the output of a clinical BCG instrument with higher reliability and accuracy compared to the previous processing methods.

Keywords: ballistocardiogram, electrocardiogram, respiration

Print publication: Issue 7 (July 2008)
Received 15 January 2008, accepted for publication 16 April 2008
Published 18 June 2008

Bookmark and Share Post to CiteUlike | Post to Connotea | Post to Bibsonomy

 

Find related articles






Article options

Authors & Referees

This Month's Papersauthor services
 
Content finder
  Full Search
  Help


  
Setup information is available for Adobe Acrobat.
EndNote, ProCite ® and Reference Manager ® are registered trademarks of ISI Researchsoft.
Copyright © Institute of Physics and IOP Publishing Limited 2009.
Use of this service is subject to compliance with the terms and conditions of use. In particular, reselling and systematic downloading of files is prohibited.
Help: Cookies | Data Protection.
 
Bioinspiration and Biomimetics reasearch banner