Electrical characterization of a dc secondary discharge created during plasma sputtering deposition of palladium thin films

A L Thomann et al 2000 Plasma Sources Sci. Technol. 9 176-182   doi: 10.1088/0963-0252/9/2/310  Help

   PDF (260 KB) | Gzipped PS (281 KB) | References | Articles citing this article

A L Thomann-+, C Charles++, N Cherradi-+ and P Brault-+
-+ GREMI-ESPEO, Université d'Orléans, 14 rue d'Issoudun, BP 6744, 45067 Orléans cedex 2, France
++ Plasma Research Laboratory, Australian National University, Acton ACT 0200, Canberra, Australia

Abstract. Good quality Pd thin films (for catalysis application) can be obtained by a low-pressure plasma sputtering method. The metal atom source is a helicoidal wire which is negatively biased so that argon ions created in a high frequency plasma are attracted and gain sufficient energy to induce sputtering. Depending on the experimental conditions (gas pressure, wire bias voltage), the sputtering process occurs in different regimes corresponding to either the presence of a simple cathodic sheath or the breakdown of an hollow cathode type discharge inside the helix. Since the flux of metal atoms condensing onto the substrate depends on the sputtering characteristics, it is of particular interest to study the formation of this secondary discharge (breakdown voltage and density profile). This is carried out by measuring the Langmuir saturation current profile inside and around the helix, and correlating the results with the determination by Rutherford backscattering spectroscopy analysis of the deposition rate on a SiO2 substrate. We also present density profiles of the argon plasma along the main axis of the reactor, which show that the flux of argon ions onto the substrate is not affected by the nature of the helix discharge. Finally, the ability to extend the range of deposition conditions (especially the ion flux to metal atom flux ratio) by using the helix diameter as an additional parameter is discussed.

Print publication: Issue 2 (May 2000)
Received 13 September 1999, in final form 21 January 2000

Bookmark and Share Post to CiteUlike | Post to Connotea | Post to Bibsonomy

 

Find related articles





Article options

Authors & Referees

BEC Matters!PW launch banner
 
Content finder
  Full Search
  Help


  
Setup information is available for Adobe Acrobat and Gzip compressed PostScript.
EndNote, ProCite ® and Reference Manager ® are registered trademarks of ISI Researchsoft.
Copyright © Institute of Physics and IOP Publishing Limited 2009.
Use of this service is subject to compliance with the Terms and Conditions of use. In particular, reselling and systematic downloading of files is prohibited.
Help: Cookies | Data Protection. Privacy policy Disclaimer
 
Bioinspiration and Biomimetics reasearch banner