journals.iop.org home page electronic journals * User guide   * Site map   | Quick Search:Help  
Measurement Science and Technology
Athens/Institutional login
IOP login: Password:   
Create account | Alerts | Contact us
Journals Home | Journals List | EJs Extra | This Journal | Search | Authors | Referees | Librarians | User Options | Help |

Improved methods and uncertainty analysis in the calibration of the spring constant of an atomic force microscope cantilever using static experimental methods

Charles A Clifford et al 2009 Meas. Sci. Technol. 20 125501 (11pp)   doi: 10.1088/0957-0233/20/12/125501  Help

   PDF (379 KB) | References

Charles A Clifford and Martin P Seah
Analytical Science Division, National Physical Laboratory, Hampton Road, Teddington, Middlesex, TW11 0LW, UK
E-mail: charles.clifford@npl.co.uk

Abstract. There are many published methods to calibrate the spring constant of an atomic force microscope (AFM) cantilever needed for quantitative force measurement. Each method has its own merits and falls within three broad categories: dimensional, static experimental and dynamic experimental. We report, here, improved static experimental methods using a one- or a two-step calibration process using readily available equipment. The one-step method uses either a nanoindenter on cantilever method or dimensional means and the two-step method uses the first step to calibrate a reference cantilever which is then used for a cantilever on reference cantilever approach relevant to laboratories with many AFMs. For both static experimental methods, multi-positional methods using four or five positions along the cantilever are described and shown in practice to have lower uncertainty than a one-position method. Full uncertainties in all the methods are discussed and shown to be dominated by the uncertainty in the first step demonstrated here with a standard uncertainty of 8%, although this could be reduced to 5%. In the second, cantilever on reference cantilever step only a further 0.6% is added in quadrature.

Keywords: spring constant, force constant, cantilever, atomic force microscope (AFM), scanning probe microscope (SPM), nanoindenter

Print publication: Issue 12 (December 2009)
Received 16 March 2009, in final form 24 September 2009
Published 6 November 2009

Bookmark and Share Post to CiteUlike | Post to Connotea | Post to Bibsonomy

 

Find related articles





Article options

Authors & Referees

PhysicsWorld, subscribe nowauthor services
 
Content finder
  Full Search
  Help


  
Setup information is available for Adobe Acrobat.
EndNote, ProCite ® and Reference Manager ® are registered trademarks of ISI Researchsoft.
Copyright © Institute of Physics and IOP Publishing Limited 2009.
Use of this service is subject to compliance with the Terms and Conditions of use. In particular, reselling and systematic downloading of files is prohibited.
Help: Cookies | Data Protection. Privacy policy Disclaimer