journals.iop.org home page electronic journals * User guide   * Site map   | Quick Search:Help  
Classical and Quantum Gravity
Athens/Institutional login
IOP login: Password:   
Create account | Alerts | Contact us
Journals Home | Journals List | EJs Extra | This Journal | Search | Authors | Referees | Librarians | User Options | Help |

Feedforward correction of mirror misalignment fluctuations for the GEO 600 gravitational wave detector

J R Smith et al 2005 Class. Quantum Grav. 22 3093-3104   doi: 10.1088/0264-9381/22/14/018  Help

   PDF (311 KB) | References | Articles citing this article

J R Smith1, H Grote1, M Hewitson1, S Hild1, H Lück1, M Parsons2,3, K A Strain2 and B Willke1
1 Max-Planck-Institute for Gravitational Physics (Albert-Einstein-Institute) and University of Hannover, Callinstr. 38, D-30167 Hannover, Germany
2 Institute for Gravitational Research, Department of Physics and Astronomy, University of Glasgow, Glasgow G12 8QQ, UK
3 Department of Zoology, University of Cambridge, Downing Street, Cambridge CB2 3EJ, UK
E-mail: joshua.smith@aei.mpg.de

Abstract. The core instrument of the GEO 600 gravitational wave detector is a Michelson interferometer with folded arms. The five main optics that form this interferometer are suspended in vacuum by triple pendulums with quasi-monolithic lower stages of fused silica. After installation of these pendulums in early 2003, a larger than expected coupling of longitudinal ground motion to tilt misalignment of the suspended optics was observed. Because of this, the uncontrolled misalignment of the optics during average conditions was several µrad Hz−1/2 in the frequency band around the pendulum resonance frequencies (0.5–4 Hz). In addition, it was found that longitudinal control signals applied to the intermediate pendulum stages also resulted in excessive mirror tilt. The resulting misalignment exceeded the level tolerable for stable operation of GEO 600. In order to reduce the level of mirror tilt, a bipartite feedforward system was implemented. One part feeds signals derived from seismic measurements to piezo-electric crystals in the stacks supporting the suspensions, reducing the longitudinal motion of the uppermost suspension points. The other applies tilt correction signals, derived from longitudinal control signals, to the intermediate level of the suspensions. The seismic feedforward correction reduces the root-mean-squared tilt misalignment of each main optic between 0.1 and 5 Hz by about 10 dB, typically. The intermediate-mass feedforward correction reduces the differential tilt misalignment of the Michelson interferometer by about 10 dB between 0.1 and 0.8 Hz, typically.

PACS numbers: 04.80.Nn, 95.55.Ym, 95.75.Kk, 02.30.Yy

Print publication: Issue 14 (21 July 2005)
Received 29 April 2005, in final form 7 June 2005
Published 6 July 2005

Bookmark and Share Post to CiteUlike | Post to Connotea | Post to Bibsonomy

 

Find related articles





Article options

Authors & Referees

IOP Journal ArchiveOptics.org banner
 
Content finder
  Full Search
  Help


  
Setup information is available for Adobe Acrobat.
EndNote, ProCite ® and Reference Manager ® are registered trademarks of ISI Researchsoft.
Copyright © Institute of Physics and IOP Publishing Limited 2009.
Use of this service is subject to compliance with the terms and conditions of use. In particular, reselling and systematic downloading of files is prohibited.
Help: Cookies | Data Protection.
 
Bioinspiration and Biomimetics reasearch banner