Filtering and calibration of data from a resonant-mass gravitational wave antenna

I S Heng et al 1999 Class. Quantum Grav. 16 3439-3456   doi: 10.1088/0264-9381/16/11/302  Help

   PDF (455 KB) | Gzipped PS (592 KB) | References | Articles citing this article

I S Heng, M E Tobar and D G Blair
Department of Physics, University of Western Australia, Nedlands, WA 6907, Australia

Abstract. Algorithms for extracting a burst gravitational wave signal embedded within the noise of resonant-mass gravitational wave antenna have been well characterized theoretically, but their effects on experimental data, which can be contaminated by non-stationary, non-Gaussian noise, are still being studied. In this paper, we study the effects of three such algorithms, the zero-order prediction, adaptive Wiener-Kolmogorov and non-adaptive Wiener-Kolmogorov algorithms, on data from the resonant-mass gravitational wave antenna, Niobe, at the University of Western Australia. By applying these filters to computer-simulated GW signals, we show that the adaptive Wiener-Kolmogorov filter gives the best noise performance and signal-to-noise ratio in the presence of non-Gaussian noise. By searching for coincidences between the simulated signals, we show that a window larger than the sampling time of the data is necessary to observe a coincidence between all events. A method of applying pulse excitations to Niobe by amplitude modulating the pump oscillator driving the parametric transducer is also described. This method has the potential to be a very accurate calibration technique but uncertainties in the input and output gains reduce its accuracy. Finally, the adaptive and non-adaptive Wiener-Kolmogorov filters are applied to pulses generated by the amplitude modulation method to determine the overall timing delays and energy uncertainties of Niobe and its data acquisition system.

PACS numbers: 0480N, 0705T

Print publication: Issue 11 (November 1999)
Received 30 April 1999

Bookmark and Share Post to CiteUlike | Post to Connotea | Post to Bibsonomy

 

Find related articles





Article options

Authors & Referees

BEC Matters!PW launch banner
 
Content finder
  Full Search
  Help


  
Setup information is available for Adobe Acrobat and Gzip compressed PostScript.
EndNote, ProCite ® and Reference Manager ® are registered trademarks of ISI Researchsoft.
Copyright © Institute of Physics and IOP Publishing Limited 2009.
Use of this service is subject to compliance with the Terms and Conditions of use. In particular, reselling and systematic downloading of files is prohibited.
Help: Cookies | Data Protection. Privacy policy Disclaimer
 
Bioinspiration and Biomimetics reasearch banner