journals.iop.org home page electronic journals * User guide   * Site map   | Quick Search:Help  
Physics in Medicine and Biology
Athens/Institutional login
IOP login: Password:   
Create account | Alerts | Contact us
Journals Home | Journals List | EJs Extra | This Journal | Search | Authors | Referees | Librarians | User Options | Help |

Selective imaging of adherent targeted ultrasound contrast agents

S Zhao et al 2007 Phys. Med. Biol. 52 2055-2072   doi: 10.1088/0031-9155/52/8/002  Help

   PDF (725 KB) | References | Articles citing this article

S Zhao, D E Kruse, K W Ferrara and P A Dayton
Department of Biomedical Engineering, University of California, Davis, USA
E-mail: kwferrara@ucdavis.edu

Abstract. The goal of ultrasonic molecular imaging is the detection of targeted contrast agents bound to receptors on endothelial cells. We propose imaging methods that can distinguish adherent microbubbles from tissue and from freely circulating microbubbles, each of which would otherwise obscure signal from molecularly targeted adherent agents. The methods are based on a harmonic signal model of the returned echoes over a train of pulses. The first method utilizes an 'image–push–image' pulse sequence where adhesion of contrast agents is rapidly promoted by acoustic radiation force and the presence of adherent agents is detected by the signal change due to targeted microbubble adhesion. The second method rejects tissue echoes using a spectral high-pass filter. Free agent signal is suppressed by a pulse-to-pulse low-pass filter in both methods. An overlay of the adherent and/or flowing contrast agents on B-mode images can be readily created for anatomical reference. Contrast-to-tissue ratios from adherent microbubbles exceeding 30 dB and 20 dB were achieved for the two methods proposed, respectively. The performance of these algorithms is compared, emphasizing the significance and potential applications in ultrasonic molecular imaging.

Print publication: Issue 8 (21 April 2007)
Received 12 October 2006, in final form 28 February 2007
Published 20 March 2007

Bookmark and Share Post to CiteUlike | Post to Connotea | Post to Bibsonomy

 


Find related articles






Article options

Authors & Referees

 
Content finder
  Full Search
  Help


  
Setup information is available for Adobe Acrobat.
EndNote, ProCite ® and Reference Manager ® are registered trademarks of ISI Researchsoft.
Copyright © Institute of Physics and IOP Publishing Limited 2009.
Use of this service is subject to compliance with the terms and conditions of use. In particular, reselling and systematic downloading of files is prohibited.
Help: Cookies | Data Protection.