journals.iop.org home page electronic journals * User guide   * Site map   | Quick Search:Help  
Physics in Medicine and Biology
Athens/Institutional login
IOP login: Password:   
Create account | Alerts | Contact us
Journals Home | Journals List | EJs Extra | This Journal | Search | Authors | Referees | Librarians | User Options | Help |

Is correction necessary when clinically determining quantitative cerebral perfusion parameters from multi-slice dynamic susceptibility contrast MR studies?*

M Salluzzi et al 2006 Phys. Med. Biol. 51 407-424   doi: 10.1088/0031-9155/51/2/015  Help

   PDF (1.14 MB) | References | Articles citing this article

M Salluzzi1, R Frayne1,2,3,4 and M R Smith1,2
1 Department of Electrical and Computer Engineering, University of Calgary, Calgary T2N 1N4, Alberta, Canada
2 Department of Radiology, University of Calgary, Calgary T2N 1N4, Alberta, Canada
3 Department of Clinical Neurosciences, University of Calgary, Calgary T2N 1N4, Alberta, Canada
4 Seaman Family MR Research Centre, Foothills Medical Centre, Calgary Health Region, Calgary T2N 2T9, Alberta, Canada
E-mail: smithmr@ucalgary.ca

Abstract. Several groups have modified the standard singular value decomposition (SVD) algorithm to produce delay-insensitive cerebral blood flow (CBF) estimates from dynamic susceptibility contrast (DSC) perfusion studies. However, new dependences of CBF estimates on bolus arrival times and slice position in multi-slice studies have been recently recognized. These conflicting findings can be reconciled by accounting for several experimental and algorithmic factors. Using simulation and clinical studies, the non-simultaneous measurement of arterial and tissue concentration curves (relative slice position) in a multi-slice study is shown to affect time-related perfusion parameters, e.g. arterial-tissue-delay measurements. However, the current clinical impact of relative slice position on amplitude-related perfusion parameters, e.g. CBF, can be expected to be small unless any of the following conditions are present individually or in combination: (a) high concentration curve signal-to-noise ratios, (b) small tissue mean transit times, (c) narrow arterial input functions or (d) low temporal resolution of the DSC image sequence. Recent improvements in magnetic resonance (MR) technology can easily be expected to lead to scenarios where these effects become increasingly important sources of inaccuracy for all perfusion parameter estimates. We show that using Fourier interpolated (high temporal resolution) residue functions reduces the systematic error of the perfusion parameters obtained from multi-slice studies.

* Preliminary results associated with this paper were presented at ISMRM 12th Scientific Meeting and Exhibition, Kyoto, Japan, 2004.

Print publication: Issue 2 (21 January 2006)
Received 3 August 2005, in final form 1 November 2005
Published 4 January 2006

Bookmark and Share Post to CiteUlike | Post to Connotea | Post to Bibsonomy

 


Find related articles






Article options

Authors & Referees

 
Content finder
  Full Search
  Help


  
Setup information is available for Adobe Acrobat.
EndNote, ProCite ® and Reference Manager ® are registered trademarks of ISI Researchsoft.
Copyright © Institute of Physics and IOP Publishing Limited 2009.
Use of this service is subject to compliance with the terms and conditions of use. In particular, reselling and systematic downloading of files is prohibited.
Help: Cookies | Data Protection.