Verification of the optimal backscatter for an aSi electronic portal imaging device

Joseph A Moore et al 2005 Phys. Med. Biol. 50 2341-2350   doi: 10.1088/0031-9155/50/10/011  Help

   PDF (2.82 MB) | References | Articles citing this article

Joseph A Moore and Jeffrey V Siebers
Department of Radiation Oncology, Medical College of Virginia Hospitals, Virginia Commonwealth University, Richmond, VA, USA
E-mail: jamoore@vcu.edu

Abstract. Electronic portal imaging devices (EPIDs), currently used for determining proper patient placement during irradiation in a radiotherapy treatment, can also be used as dosimeters. However, the Varian aS500 portal imager exhibits dosimetric artefacts caused by non-uniform backscatter from mechanical support structures located behind the imager. Monte Carlo simulations predict that adding 5 mm of Pb behind the imaging cassette will reduce the non-uniform backscatter to <1% for 6 MV and to <1.5% for 18 MV photon beams. This study experimentally tested this hypothesis by comparing images using an unmodified test imager and an imager modified by adding 3 and 5 mm of Pb behind the imaging cassette. Using the modified imager containing 5 mm of Pb, the non-uniform backscatter was reduced to <0.5% for 6 MV and <0.6% for 18 MV beams. Addition of the 5 mm of Pb increased the detector contrast by 3.5% ± 0.5% at 6 MV and 5.0% ± 0.7% at 18 MV, and increased the resolution by 0.9% ± 0.2% at 6 MV and 0.5% ± 0.12% at 18 MV.

Print publication: Issue 10 (21 May 2005)
Received 30 November 2004, in final form 8 March 2005
Published 5 May 2005

Bookmark and Share Post to CiteUlike | Post to Connotea | Post to Bibsonomy

 


Find related articles






Article options

Authors & Referees

 
Content finder
  Full Search
  Help


  
Setup information is available for Adobe Acrobat.
EndNote, ProCite ® and Reference Manager ® are registered trademarks of ISI Researchsoft.
Copyright © Institute of Physics and IOP Publishing Limited 2009.
Use of this service is subject to compliance with the terms and conditions of use. In particular, reselling and systematic downloading of files is prohibited.
Help: Cookies | Data Protection.