journals.iop.org home page electronic journals * User guide   * Site map   | Quick Search:Help  
Physics in Medicine and Biology
Athens/Institutional login
IOP login: Password:   
Create account | Alerts | Contact us
Journals Home | Journals List | EJs Extra | This Journal | Search | Authors | Referees | Librarians | User Options | Help |

Near-infrared optical properties of ex vivo human skin and subcutaneous tissues measured using the Monte Carlo inversion technique

C Rebecca Simpson et al 1998 Phys. Med. Biol. 43 2465-2478   doi: 10.1088/0031-9155/43/9/003  Help

   PDF (243 KB) | Gzipped PS (257 KB) | References | Articles citing this article

C Rebecca Simpson-+, Matthias Kohl-+, Matthias Essenpreis|| and Mark Cope-+
-+ University College London, Department of Medical Physics and Bioengineering, London WC1E 6JA, UK
|| Boehringer Mannheim GmbH, D 63305, Germany

Abstract. The absorption and transport scattering coefficients of caucasian and negroid dermis, subdermal fat and muscle have been measured for all wavelengths between 620 and 1000 nm. Samples of tissue 2 mm thick were measured ex vivo to determine their reflectance and transmittance. A Monte Carlo model of the measurement system and light transport in tissue was then used to recover the optical coefficients. The sample reflectance and transmittance were measured using a single integrating sphere `comparison' method. This has the advantage over conventional double-sphere techniques in that no corrections are required for sphere properties, and so measurements sufficiently accurate to recover the absorption coefficient reliably could be made. The optical properties of caucasian dermis were found to be approximately twice those of the underlying fat layer. At 633 nm, the mean optical properties over 12 samples were and for absorption coefficient and and for transport scattering coefficient for caucasian dermis and the underlying fat layer respectively. The transport scattering coefficient for all biological samples showed a monotonic decrease with increasing wavelength. The method was calibrated using solid tissue phantoms and by comparison with a temporally resolved technique.

Print publication: Issue 9 (September 1998)
Received 31 July 1997, in final form 18 May 1998

Bookmark and Share Post to CiteUlike | Post to Connotea | Post to Bibsonomy

 


Find related articles






Article options

Authors & Referees

 
Content finder
  Full Search
  Help


  
Setup information is available for Adobe Acrobat and Gzip compressed PostScript.
EndNote, ProCite ® and Reference Manager ® are registered trademarks of ISI Researchsoft.
Copyright © Institute of Physics and IOP Publishing Limited 2009.
Use of this service is subject to compliance with the Terms and Conditions of use. In particular, reselling and systematic downloading of files is prohibited.
Help: Cookies | Data Protection. Privacy policy Disclaimer