Final report on CCQM-K9.2: Subsequent key comparison on pH determination of phosphate buffer by Harned cell measurements

Petra Spitzer et al 2008 Metrologia 45 08006   doi: 10.1088/0026-1394/45/1A/08006  Help


Petra Spitzer1,7, Janine Giera1, Isabel C Fraga2, Pia Tønnes Jakobsen3, Hans D Jensen3, Peter Hyllested3, Oleg Karpov4, Viatcheslav Kutovoy4, Susumu Nakamura5, Alena Vospelova6 and Valentina Zvezdina4
1 Physikalisch-Technische Bundesanstalt (PTB), Germany
2 INMETRO, Brazil
3 Danish Institute of Fundamental Metrology, Denmark
4 National Research Institute for Physical-Technical and Radio-technical Measurements (VNIIFTRI), Russia
5 National Metrology Institute of Japan (NMIJ), Japan
6 Czech Metrology Institute, Czech Republic
7 Coordinator.

Abstract. CCQM-K9.2 was performed supplementary to the key comparison CCQM-K9 on the pH determination of a phosphate buffer with nominal pH ~ 6.9 (at 25 °C). The sample composition was very similar in both comparisons. Only the source of the starting material used for sample preparation was different. The comparison was restricted to the use of the primary method for pH (Harned cell measurement) as defined in the IUPAC Recommendations [2]. The measurement temperatures were 15 °C, 25 °C, 37 °C.

CCQM-K9.2, CCQM-K.9 and the first supplementary comparison CCQM-K9.1 [5] are activities of the Electrochemical Working Group (EAWG) of the CCQM. All three comparisons were coordinated by the PTB, Germany.

The Danish Primary Laboratory (DPL) successfully took part in the CCQM-K9. Meanwhile the primary set-up for pH in Denmark moved from DPL affiliated to Radiometer Medical to DFM, Denmark. The subsequent comparison allows assessing the degree of equivalence for the measurement of pH at DFM after the move. Due to the interest of other laboratories in demonstrating their progress in pH measurements on the primary level the CCQM-K9.2 supplementary comparison was extended to other participants than DFM, namely NMIJ, VNIIFTRI, INMETRO and CMI.

The reported quantity for CCQM-K9.2 was not the pH of the sample but the acidity function at zero chloride molality (see chapter 12). To calculate the pH value from the acidity function it is necessary to know the ionic strength of the sample buffer solution, which was undisclosed by the coordinator.

With the exception of the Czech Metrology Institute, CMI, good agreement in the determined acidity function is found between the participants.

The results reported by DFM and by PTB agree within their measurement uncertainty at all measurement temperatures.

Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/.

The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).

Bookmark and Share Post to CiteUlike | Post to Connotea | Post to Bibsonomy

 

Find related articles





Article options

Authors & Referees

BEC Matters!Optics.org banner
 
Content finder
  Full Search
  Help


  
EndNote, ProCite ® and Reference Manager ® are registered trademarks of ISI Researchsoft.
Copyright © Institute of Physics and IOP Publishing Limited 2009.
Use of this service is subject to compliance with the terms and conditions of use. In particular, reselling and systematic downloading of files is prohibited.
Help: Cookies | Data Protection.