KEY COMPARISON

Final report on comparison COOMET.T-K3: Regional comparisons of the national standards of temperature in the range from the triple point of water to the freezing temperature of zinc

A I Pokhodun et al 2008 Metrologia 45 03005   doi: 10.1088/0026-1394/45/1A/03005  Help


A I Pokhodun and A G Ivanova
D I Mendeleyev Institute of Metrology, 19, Moskovskii pr., St Petersburg, Russia
E-mail: A.I.Pokhodun@vniim.ru

Abstract. The COOMET.T-K3 comparison is the regional comparison of the defining fixed points realization in the range from the triple point of water to the freezing point of zinc. Four national metrology institutes—VNIIM (pilot), SMU, BelGIM and NNC IM—took part in the COOMET regional comparisons. At the first stage the cells of fixed points of the national metrology institutes were used as transfer standards. They were compared with the VNIIM cells by means of standard platinum resistance thermometers using the VNIIM standard setups and equipment. At the second stage the equivalence of realization of the fixed points at the national institutes was estimated. A standard platinum resistance thermometer SPRT (25 ohm), manufactured at VNIIM, was used as a transfer standard.

The degree of equivalence of the measurement standard of the national metrology institutes participating in the COOMET comparison is determined relative to the reference values of the CCT-K3 through the measurement results received in the linking national metrology institutes, VNIIM and SMU, which took part in both comparisons. The values 'ARV' of K3 were assumed as the reference values. The report presents the results of this comparison and gives detailed information about the method of estimation of the degree of equivalence of NMI standards and its uncertainty.

Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/.

The final report has been peer-reviewed and approved for publication by the CCT, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).

Bookmark and Share Post to CiteUlike | Post to Connotea | Post to Bibsonomy

 

Find related articles





Article options

Authors & Referees

This Month's Papersauthor services
 
Content finder
  Full Search
  Help


  
EndNote, ProCite ® and Reference Manager ® are registered trademarks of ISI Researchsoft.
Copyright © Institute of Physics and IOP Publishing Limited 2009.
Use of this service is subject to compliance with the terms and conditions of use. In particular, reselling and systematic downloading of files is prohibited.
Help: Cookies | Data Protection.