SUPPLEMENTARY COMPARISON

Final report on the fixed-point comparison of Au/Pt thermocouples (APMP supplementary comparison APMP.T-S4)

Yong-Gyoo Kim et al 2008 Metrologia 45 03004   doi: 10.1088/0026-1394/45/1A/03004  Help


Yong-Gyoo Kim1, Hans Liedberg2 and Ferdouse Jahan3
1 Korea Research Institute of Standards and Science (KRISS), Korea
2 National Measurement Institute of South Africa (NMISA), South Africa
3 National Measurement Institute of Australia (NMIA), Australia

Abstract. The Au/Pt thermocouple is the most accurate thermocouple in the temperature range of 0 to 1000 °C and is widely used in many NMIs (national measurement institutes) to disseminate the ITS-90 temperature scale in their countries. Over the years, there has been no comparison on this thermocouple within the APMP region. The objective of this comparison is to assess the degree of equivalence of the calibration results at the ITS-90 fixed-points of Ga, Sn, Zn, Al and Ag. This is a round robin comparison involving three NMIs—KRISS, NMISA and NMIA. KRISS was invited to be the pilot laboratory and was asked to prepare the two artifacts (Au/Pt thermocouple) to be circulated. This report describes the measurement procedures and equipment used in each laboratory, and compares the results and associated uncertainties obtained from the measurements by the participants. The maximum deviation at different fixed points among the three laboratories is in the range of 10 mK to 60 mK. This comparison can be used as a pilot study for another forthcoming comparison on the Au/Pt thermocouples including more participants in the APMP region.

Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/.

The final report has been peer-reviewed and approved for publication by the APMP, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).

Bookmark and Share Post to CiteUlike | Post to Connotea | Post to Bibsonomy

 

Find related articles





Article options

Authors & Referees

Nanotechnology news and resourceseprintweb.org - Your address for E prints
 
Content finder
  Full Search
  Help


  
EndNote, ProCite ® and Reference Manager ® are registered trademarks of ISI Researchsoft.
Copyright © Institute of Physics and IOP Publishing Limited 2009.
Use of this service is subject to compliance with the terms and conditions of use. In particular, reselling and systematic downloading of files is prohibited.
Help: Cookies | Data Protection.