| Journals Home | Journals List | EJs Extra | This Journal | Search | Authors | Referees | Librarians | User Options | Help | | ||||
SUPPLEMENTARY COMPARISON
2008 Metrologia 45 01011 doi: 10.1088/0026-1394/45/1A/01011
![]()
Abstract. A comparison of the 10 V Josephson array voltage standard of the Physikalisch-Technische Bundesanstalt (PTB), Germany, was made with that of the Primarni Elektromagnetski Laboratorij (PEL), Croatia, in April 2007. The results are in very good agreement and the measured overall relative combined standard uncertainty is better than 1 part in 1010.
Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/.
The final report has been peer-reviewed and approved for publication by EURAMET, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).
| Post to CiteUlike | | Post to Connotea | | Post to Bibsonomy |
|
Journals Home | Journals List | EJs Extra | This Journal | Search | Authors | Referees | Librarians | User Options | Help | Recommend this journal Copyright © Institute of Physics and IOP Publishing Limited 2009. Use of this service is subject to compliance with the Terms and Conditions of use. In particular, reselling and systematic downloading of files is prohibited. Help: Cookies | Data Protection. Privacy policy Disclaimer |