journals.iop.org home page electronic journals * User guide   * Site map   | Quick Search:Help  
Metrologia
Athens/Institutional login
IOP login: Password:   
Create account | Alerts | Contact us
Journals Home | Journals List | EJs Extra | This Journal | Search | Authors | Referees | Librarians | User Options | Help |

KEY COMPARISON

Update of the BIPM comparison BIPM.RI(II)-K1.Am-241 of activity measurements of the radionuclide 241Am to include the 2006 VNIIM result, links for the 2003 international comparison CCRI(II)-K2.Am-241 and links for the 2006 regional comparison COOMET.RI(II)-K2.Am-241

G Ratel et al 2007 Metrologia 44 06007   doi: 10.1088/0026-1394/44/1A/06007  Help


G Ratel1, C Michotte1, L Johansson2, S Judge2 and I A Kharitonov3
1 Bureau International des Poids et Mesures (BIPM), Pavillon de Breteuil, 92312 Sèvres cedex, France
2 National Physicsal Laboratory (NPL), UK
3 D I Mendeleyev Institute for Metrology (VNIIM), Russian Federation

Abstract. Since 1977, seven national metrology institutes (NMIs) have submitted eleven samples of known activity of 241Am to the International Reference System (SIR) for activity comparison at the Bureau International des Poids et Mesures (BIPM). The activities ranged from about 1.9 MBq to 17 MBq. The results of the CCRI(II)-K2.Am-241 comparison held in 2003 with twenty-one participants have been linked to the BIPM.RI(II)-K1.Am-241 results using the submission to the SIR by the NPL of two ampoules of the mother solution of the CCRI(II) comparison. This has enabled four NMIs to update their earlier SIR results and fifteen NMIs, the IRMM and the BIPM to have their result published, the previous international comparison of 241Am having been held over 40 years ago. The results of a COOMET.RI(II)-K2.Am-241 comparison held in 2006 have also been linked to the SIR results. This is possible through the submission to the SIR of an ampoule of the comparison by the pilot laboratory, the VNIIM. This has enabled two further NMIs to have degrees of equivalence for activity measurements for this radionuclide. The key comparison reference value (KCRV) has been updated to include the recent NPL and VNIIM results. The degree of equivalence between each equivalent activity measured in the SIR, or linked to the SIR, and the KCRV has been calculated and the results are given in the form of a matrix. A graphical presentation is also given. Degrees of equivalence between pairs of participants are similarly given as a matrix.

Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/.

The final report has been peer-reviewed and approved for publication by the CCRI(II), according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).

Bookmark and Share Post to CiteUlike | Post to Connotea | Post to Bibsonomy

 

Find related articles





Article options

Authors & Referees

BEC Matters!author services
 
Content finder
  Full Search
  Help


  
EndNote, ProCite ® and Reference Manager ® are registered trademarks of ISI Researchsoft.
Copyright © Institute of Physics and IOP Publishing Limited 2009.
Use of this service is subject to compliance with the Terms and Conditions of use. In particular, reselling and systematic downloading of files is prohibited.
Help: Cookies | Data Protection. Privacy policy Disclaimer