The use of a Monte Carlo method for evaluating uncertainty and expanded uncertainty

Maurice G Cox et al 2006 Metrologia 43 S178-S188   doi: 10.1088/0026-1394/43/4/S03  Help

   PDF (298 KB) | References | Articles citing this article

Maurice G Cox1 and Bernd R L Siebert2
1 National Physical Laboratory, Teddington, Middlesex TW11 0LW, UK
2 Physikalisch-Technische Bundesanstalt, 38116 Braunschweig, Germany

Abstract. The Guide to the Expression of Uncertainty in Measurement (GUM) is the internationally accepted master document for the evaluation of uncertainty. It contains a procedure that is suitable for many, but not all, uncertainty evaluation problems met in practice. This procedure constitutes an approximation to the general solution of the Markov formula, which infers the probability density function (PDF) for the output quantities (measurands) from the model of the measurement and the PDFs for the input quantities. This paper shows that a Monte Carlo method is an effective and versatile tool for determining the PDF for the measurands. This method provides a consistent Bayesian approach to the evaluation of uncertainty. Although in principle straightforward, some care is required in representing and validating the results obtained using the method. The paper provides guidance on optimizing the approach, identifies some pitfalls and indicates means for validating the results.

Print publication: Issue 4 (August 2006)
Received 18 May 2006
Published 4 August 2006

Bookmark and Share Post to CiteUlike | Post to Connotea | Post to Bibsonomy

 

Find related articles





Article options

Authors & Referees

This Month's PapersOptics.org banner
 
Content finder
  Full Search
  Help


  
Setup information is available for Adobe Acrobat.
EndNote, ProCite ® and Reference Manager ® are registered trademarks of ISI Researchsoft.
Copyright © Institute of Physics and IOP Publishing Limited 2009.
Use of this service is subject to compliance with the terms and conditions of use. In particular, reselling and systematic downloading of files is prohibited.
Help: Cookies | Data Protection.