journals.iop.org home page electronic journals * User guide   * Site map   | Quick Search:Help  
Metrologia
Athens/Institutional login
IOP login: Password:   
Create account | Alerts | Contact us
Journals Home | Journals List | EJs Extra | This Journal | Search | Authors | Referees | Librarians | User Options | Help |

Study and comparison of two polishing methods for platinum–iridium surfaces, by means of three characterization techniques

Y Haidar et al 2005 Metrologia 42 115-128   doi: 10.1088/0026-1394/42/2/006  Help

   PDF (1.15 MB) | References | Articles citing this article

Y Haidar1, E Tollens2, Z Silvestri2, F de Fornel1, C Zerrouki2,3, A Picard4 and P Pinot2
1 OCP-LPUB CNRS UFR 5027, 9 av Alain Savary, BP 47870, 21078 Dijon, France
2 BNM-INM/Cnam, 292 rue Saint-Martin, 75141 Paris, Cedex 03, France
3 Laboratoire de Physique/Cnam, 2 rue Conté, 75003 Paris, France
4 BIPM, Pavillon de Breteuil, F-92312 Sèvres Cedex, France

Abstract. Machining the surface of mass standards is still of great importance. This paper details a comparative study of the roughness of two plane surfaces of a platinum–iridium alloy (90% of platinum and 10% of iridium). Using the BIPM processes, the surfaces were initially machined on a lathe using diamond tools; in addition, one of these was manually polished with a diamond paste.

Three techniques for surface characterization are used: shear-force microscopy (ShFM), optical roughness-meter and x-ray reflectometer. The first technique uses the shear-force interaction between the probe and the sample. The ShFM is part of a scanning near-field optical microscope that has the advantage of providing two images simultaneously, a topographical one and a near-field optical one. Only the topographic images will be presented in this paper; the results obtained in optical near-field will be the subject of another publication. To avoid any confusion, we will speak here of ShFM. The topographic images and their associated statistical and physical parameters, such as power spectral densities (PSDs), root-mean-square height, etc, are discussed in this paper. The PSDs of the surface are also determined experimentally from x-ray and visible light scattering measurements using angle-resolved scattering theory. This theory, which is well adapted for visible radiation, is extended to x-rays. The measurements made with the three instruments demonstrate that the two surfaces present a roughness of the same order of magnitude. However, the defects that contribute in a preponderant manner to their roughness spectrum do not belong to the same spatial bandwidth but depend on the polishing process.

Print publication: Issue 2 (April 2005)
Received 12 October 2004
Published 9 March 2005

Bookmark and Share Post to CiteUlike | Post to Connotea | Post to Bibsonomy

 

Find related articles





Article options

Authors & Referees

PhysicsWorld, subscribe noweprintweb.org - Your address for E prints
 
Content finder
  Full Search
  Help


  
Setup information is available for Adobe Acrobat.
EndNote, ProCite ® and Reference Manager ® are registered trademarks of ISI Researchsoft.
Copyright © Institute of Physics and IOP Publishing Limited 2009.
Use of this service is subject to compliance with the terms and conditions of use. In particular, reselling and systematic downloading of files is prohibited.
Help: Cookies | Data Protection.