KEY COMPARISON

EUROMET project no 429: Comparison of 10 V electronic voltage standards

F Liefrink et al 2003 Metrologia 40 01004   doi: 10.1088/0026-1394/40/1A/01004  Help


F Liefrink1, E F Dierikx1, J W Heimeriks1, G Eklund2, I Flouda3, T Funck4, P Helistö5, A Jakab6, J-T Janssen7, B Jeanneret8, H D Jensen9, P O Hetland10, M Lindic11, J-P Lo-Hive12, J Nicolas13, M Nunes14, O Power15, F I Raso Alonso16, D Reymann17, S Selçik18, J Streit19, P Vrabcek20 and W Waldmann21
1 NMi Van Swinden Laboratorium (Pilot laboratory), The Netherlands
2 Swedish National Testing and Research Institute, Sweden
3 Hellenic Institute of Metrology, Greece
4 Physikalisch-Technische Bundesanstalt, Germany
5 Centre for Metrology and Accreditation, Finland
6 National Office of Measures Hungary
7 National Physical Laboratory, UK
8 Swiss Federal Office of Metrology and Accreditation, Switzerland
9 Danish Institute of Fundamental Metrology, Denmark
10 Norwegian Metrology and Accreditation Service Norway
11 Slovenian Institute of Quality and Metrology, Slovenia
12 BNM - Laboratoire National d'Essais, France
13 Service de la Métrologie, Belgium
14 Instituto Nacional de Engenharia e Tecnologia Industrial, Portugal
15 National Metrology Laboratory, Ireland
16 Centro Español de Metrologia, Spain
17 Bureau International des Poids et Mesures, France
18 Ulusal Metroloji Institüsü, Turkey
19 Czech Metrology Institute, Czech Republic
20 Slovak Institute of Metrology, Slovakia
21 Bundesamt für Eich- und Vermessungswesen, Austria

Abstract. This report presents the results of a comparison of measurements on four electronic DC reference standards performed by national metrology institutes in the EUROMET region and BIPM. The results of the comparison, in terms of degrees of equivalence, show that there is a good agreement between the measurement results of the participants. The results also show that the time-dependent fluctuations in the output voltages of the travelling standards provide one of the main sources of uncertainty.

Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/.

The final report has been peer-reviewed and approved for publication by the EUROMET, comparison identifier EUROMET.EM.BIPM-K11, according to the provisions of the Mutual Recognition Arrangement (MRA).

Bookmark and Share Post to CiteUlike | Post to Connotea | Post to Bibsonomy

 

Find related articles





Article options

Authors & Referees

This Month's Papersauthor services
 
Content finder
  Full Search
  Help


  
EndNote, ProCite ® and Reference Manager ® are registered trademarks of ISI Researchsoft.
Copyright © Institute of Physics and IOP Publishing Limited 2009.
Use of this service is subject to compliance with the Terms and Conditions of use. In particular, reselling and systematic downloading of files is prohibited.
Help: Cookies | Data Protection. Privacy policy Disclaimer