journals.iop.org home page electronic journals * User guide   * Site map   | Quick Search:Help  
Metrologia
Athens/Institutional login
IOP login: Password:   
Create account | Alerts | Contact us
Journals Home | Journals List | EJs Extra | This Journal | Search | Authors | Referees | Librarians | User Options | Help |

International comparisons of He-Ne lasers stabilized with 127I2 at λ = 633 nm (July 1993 to September 1995). Part VI: Comparison of VNIIM (Russian Federation), NCM (Bulgaria), NMS (Norway), NILPRP (Romania) and BIPM lasers at λ = 633 nm

L Abramova et al 2000 Metrologia 37 115-120   doi: 10.1088/0026-1394/37/2/3  Help

   PDF (204 KB) | Gzipped PS (226 KB) | References | Articles citing this article

L Abramova, Yu Zakharenko, V Fedorine, T Blajev, S Kartaleva, H Karlsson, G H Popescu, A Chartier and J-M Chartier
VNIIM, NCM, NMS, NILPRP, BIPM

Abstract. This paper reports the sixth set of results of a series of grouped laser comparisons from national laboratories undertaken by the Bureau International des Poids et Mesures (BIPM) at the request of the Comité Consultatif pour la Définition du Mètre (CCDM, now the Consultative Committee for Length, CCL), during the period July 1993 to September 1995.

The results of this comparison, involving six lasers from four countries and the BIPM, with the exception of one laser meet the goals set by the CCDM in 1992 and adopted by the Comité International des Poids et Mesures (CIPM) the same year. The standard uncertainty of the frequency of the He-Ne laser stabilized on the saturated absorption of 127I2 at λ = 633 nm is reduced to a level of 12 kHz (2.5 parts in 1011) when the lasers compared meet the recommended values of the parameters.

The lasers were first compared with the BIPM4 laser with the operating parameters set to the values normally used in each laboratory. Using the BIPM4 laser as a reference the results ranged from -108.9 kHz to 44.5 kHz. After checking and readjusting the values of all the parameters, the range was reduced to -34.5 kHz to +1.1 kHz. Under the latter conditions, the average frequency difference of the group of lasers with respect to the BIPM4 laser was -7.5 kHz with a standard uncertainty (1 σ) of 15.1 kHz. The best relative frequency stabilities, with Allan standard deviations of about 1.7 × 10-12 and 2.2 × 10-13, were observed with sampling times of 10 s and 1000 s, respectively. The overall best value was 1.1 × 10-13 for a sampling time of 3000 s.

Print publication: Issue 2 (April 2000)

Bookmark and Share Post to CiteUlike | Post to Connotea | Post to Bibsonomy

 

Find related articles





Article options

Authors & Referees

IOP Journal ArchivePW launch banner
 
Content finder
  Full Search
  Help


  
Setup information is available for Adobe Acrobat and Gzip compressed PostScript.
EndNote, ProCite ® and Reference Manager ® are registered trademarks of ISI Researchsoft.
Copyright © Institute of Physics and IOP Publishing Limited 2009.
Use of this service is subject to compliance with the Terms and Conditions of use. In particular, reselling and systematic downloading of files is prohibited.
Help: Cookies | Data Protection. Privacy policy Disclaimer