INTERNATIONAL REPORT
1994 Metrologia 31 149-153 doi: 10.1088/0026-1394/31/2/009
![]()
|
||||
Abstract. A revised table of differences (t90 - t68) between values of temperature on the International Temperature Scale of 1990, ITS-90, and the corresponding values on the International Practical Temperature Scale of 1968, IPTS-68, is published at the request of the Comité Consultatif de Thermométrie (CCT). The revision affects only the range 630°C to 1064°C, where the IPTS-68 specified the use of platinum-10% rhodium versus platinum thermocouples. It follows from new intercomparisons of thermocouples carrying IPTS-68 calibrations with platinum resistance thermometers and radiation thermometers calibrated in accordance with the ITS-90. The largest change occurs at 760°C, where the difference formerly tabulated as 0,36°C is now 0,04°C. The revision concerns only the assessment of the differences between the ITS-90 and the IPTS-68, and does not affect the ITS-90 in any way.
Print publication: Issue 2 (1994)| Post to CiteUlike | | Post to Connotea | | Post to Bibsonomy |
|
Journals Home | Journals List | EJs Extra | This Journal | Search | Authors | Referees | Librarians | User Options | Help | Recommend this journal EndNote, ProCite ® and Reference Manager ® are registered trademarks of ISI Researchsoft. Copyright © Institute of Physics and IOP Publishing Limited 2009. Use of this service is subject to compliance with the Terms and Conditions of use. In particular, reselling and systematic downloading of files is prohibited. Help: Cookies | Data Protection. Privacy policy Disclaimer |